Transfer
Here is a selection of → KNF pumps for the hydrogen value chain and fuel cell systems that can be used for the transfer of the following media:
→ Methanol, methanol-water solution
→ Potash
Methanol, Methanol-water Solution
The following KNF pumps can be used for transferring methanol and methanol-water solutions:
NF 5
FL 10
NF 25
Flow rate: max. 0.07 l/min
Suction height: max. 3 mH2O
Operating pressure: max. 1 bar (rel.)
![NF 5](/fileadmin/_processed_/6/3/csm_OEM_Product_NF_5_KPDCB-4_side_2020_1200px_900px_9938266f20.png)
Flow rate: max. 0.1 l/min
Suction height: max. 2 mH2O
Operating pressure: max. 1 bar (rel.)
![FL 10](/fileadmin/_processed_/9/d/csm_OEM_Product_FL_10_KPDC-P_side_2023_1200px_900px_e8dd9317b6.jpg)
Flow rate: max. 0.25 l/min
Suction height: max. 3 mH2O
Operating pressure: max. 1 bar (rel.)
![NF 25](/fileadmin/_processed_/5/f/csm_OEM_Product_NF_25_KPDCB-4_side_2020_1200px_900px_4bd283bbbd.png)
NF 1.25
NF 60
FK 1.1100
Flow rate: max. 0.3 l/min
Suction height: max. 3 mH2O
Operating pressure: max. 6 bar (rel.)
![NF 1.25](/fileadmin/_processed_/2/7/csm_OEM_Product_NF_1.25_RPDCB-4B_side_2020_1200px_900px_f09ce70356.png)
Flow rate: max. 0.6 l/min
Suction height: max. 3 mH2O
Operating pressure: max. 1 bar (rel.)
![NF 60](/fileadmin/_processed_/e/d/csm_OEM_Product_NF_60_KPDCB-4B__side_2020_1200px_900px_d7e8bd70ba.png)
Flow rate: max. 12.4 l/min
Suction height: max. 4.5 mH2O
Operating pressure: max. 6 bar (rel.)
![FK 1.1100](/fileadmin/_processed_/b/8/csm_OEM_Product_fk_1.1100_KPDCB-4_side_2020_1200xpx_900px_120a95b0d5.png)
Oxygen, Cathode Air
The following KNF pumps can be used for transferring oxygen and cathode air:
NMP 820
NMP 830
NMP 850.1.2
Flow rate: max. 2.1 l/min
Ultimate vacuum: max. 330 mbar (abs.)
Operating pressure: max. 1.2 bar (rel.)
![NMP 820](/fileadmin/_processed_/7/7/csm_OEM_Product_NMP_820_KDC-B_side_1200x900px_f13ebba339.png)
Flow rate: max. 3.1 l/min
Ultimate vacuum: max. 250 mbar (abs.)
Operating pressure: max. 1.4 bar (rel.)
![NMP 830](/fileadmin/_processed_/3/d/csm_OEM_Product_NMP830K_DC-B_I_1200_900px_5557b42b27.png)
Flow rate: max. 8.5 l/min
Ultimate vacuum: max. 60 mbar (abs.)
Operating pressure: max. 2.5 bar (rel.)
![NMP 850.1.2](/fileadmin/_processed_/4/4/csm_OEM_Product_NMP_850.1.2KPDC-BI_1200px_900px_831df2a150.png)
NMP 830.1.2 HP
NMS 030
Flow rate: max. 9 l/min
Ultimate vacuum: max. 55 mbar (abs.)
Operating pressure: max. 3 bar (rel.)
![NMP 830.1.2 HP](/fileadmin/_processed_/d/4/csm_OEM_Product_NMP830.1.2KPDC-B_HP_KM32_side_2020_1200px_900px_007ad5f76f.png)
Flow rate: max. 12 l/min
Ultimate vacuum: max. 220 mbar (abs.)
Operating pressure: max. 0.2 bar (rel.)
![NMS 030](/fileadmin/_processed_/5/2/csm_OEM_Product_NMS_030_DCB-4L_side_2020_1200px_900px_af5af12ce7.png)
Condensate
The following KNF pumps can be used for transferring condensate:
FF 20
NF 30
FP 1.150
Flow rate: max. 0.23 l/min
Suction height: max. 3.5 mH2O
Operating pressure: max. 3 bar (rel.)
![FF 20](/fileadmin/_processed_/0/7/csm_OEM_Product_FF_20_KPDCB-4_side_2020_1200x900px_aa9b174e36.png)
Flow rate: max. 0.3 l/min
Suction height: max. 6 mH2O
Operating pressure: max. 1 bar (rel.)
![NF 30](/fileadmin/_processed_/6/c/csm_OEM_Product_NF_30_KPDCB-4B_side_2020_1200px_900px_bc019bcd68.png)
Flow rate: max. 1.1 l/min
Suction height: max. 2.3 mH2O
Operating pressure: max. 6 bar (rel.)
![FP 1.150](/fileadmin/_processed_/7/a/csm_OEM_Product_FP_150_side_2020_1200x900px_9f90b0199f.png)
Process Water
The following KNF pumps can be used for transferring process water:
FEM 1.02
FEM 1.09
NF 1.25
FP 70
FK 1.1100
Flow rate: max. 0.02 l/min
Suction height: max. 4 mH2O
Operating pressure: max. 6 bar (rel.)
![FEM 1.02](/fileadmin/_processed_/0/3/csm_OEM_Product_FEM_1.02_KP.27SM-2_side_2020_1200x900px_a6c32ce59b.png)
Flow rate: max. 0.09 l/min
Suction height: max. 4 mH2O
Operating pressure: max. 6 bar (rel.)
![FEM 1.09](/fileadmin/_processed_/4/5/csm_OEM_Product_FEM_1.09_KPSM-2_side_2020_1200x900px_ff2c007df4.png)
Flow rate: max. 0.3 l/min
Suction height: max. 3 mH2O
Operating pressure: max. 6 bar (rel.)
![NF 1.25](/fileadmin/_processed_/2/7/csm_OEM_Product_NF_1.25_RPDCB-4B_side_2020_1200px_900px_f09ce70356.png)
Flow rate: max. 0.85 l/min
Suction height: max. 3 mH2O
Operating pressure: max. 2 bar (rel.)
![FP 70](/fileadmin/_processed_/6/9/csm_OEM_Product_FP_70_front_2021_1200x900px_ab99793941.png)
Flow rate: max. 12.4 l/min
Suction height: max. 4.5 mH2O
Operating pressure: max. 6 bar (rel.)
![FK 1.1100](/fileadmin/_processed_/b/8/csm_OEM_Product_fk_1.1100_KPDCB-4_side_2020_1200xpx_900px_120a95b0d5.png)
Potash
The following KNF pumps can be used for transferring potash:
NF 60
FP 1.150
Flow rate: max. 0.6 l/min
Suction height: max. 3 mH2O
Operating pressure: max. 1 bar (rel.)
![NF 60](/fileadmin/_processed_/e/d/csm_OEM_Product_NF_60_KPDCB-4B__side_2020_1200px_900px_d7e8bd70ba.png)
Flow rate: max. 1.1 l/min
Suction height: max. 2.3 mH2O
Operating pressure: max. 6 bar (rel.)
![FP 1.150](/fileadmin/_processed_/7/a/csm_OEM_Product_FP_150_side_2020_1200x900px_9f90b0199f.png)
Catalyst Ink
The following KNF pumps can be used for transferring catalyst ink:
FMM 20
FP 70
FP 150
FP 400
Flow rate: max. 0.018 l/min
Suction height: max. 3 mH2O
Operating pressure: max. 1 bar (rel.)
![FMM 20](/fileadmin/_processed_/1/c/csm_FMM20_KPDC-P_2015_1200_900px_9955c07572.png)
Flow rate: max. 0.85 l/min
Suction height: max. 3 mH2O
Operating pressure: max. 2 bar (rel.)
![FP 70](/fileadmin/_processed_/6/9/csm_OEM_Product_FP_70_front_2021_1200x900px_ab99793941.png)
Flow rate: max. 1.5 l/min
Suction height: max. 2.7 mH2O
Operating pressure: max. 2 bar (rel.)
![FP 150](/fileadmin/_processed_/7/a/csm_OEM_Product_FP_150_side_2020_1200x900px_9f90b0199f.png)
Flow rate: max. 4.6 l/min
Suction height: max. 3 mH2O
Operating pressure: max. 1 bar (rel.)
![FP 400](/fileadmin/_processed_/7/c/csm_OEM_Product_FP_400_KPDCB-4_side_2020_1200px_900px_1c62222052.png)